If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Current Transducer HAL 50..600-S For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation between the primary (high power) circuit and the secondary (electronic) circuit. IPN = 50 A Electrical data Primary nominal r.m.s. current IPN (A) 50 100 200 300 400 500 600 Primary current measuring range IP (A) 150 300 600 900 1000 1000 1000 Type Features HAL HAL HAL HAL HAL HAL HAL 50-S 100-S 200-S 300-S 400-S 500-S 600-S * Open loop transducer using Hall Effect * Panel mounting - Horizontal or Vertical * Insulated plastic case to UL 94-V0. 30000 4 >1 >3 15 25 500 3 > 500 A V kW kW V mA V kV MW IP VOUT RL VC IC Vb Vd Ris Overload capacity (Ampere Turns) Analogue output voltage @ IPN Load resistance TA = 0 .. + 70C TA = - 25 .. + 85C Supply voltage ( 5 %) Current consumption (max) Rms rated voltage1) Rms voltage for AC isolation test, 50 Hz, 1 mn Isolation resistance @ 500 VDC Advantages * Very good linearity * Very good accuracy * Low temperature drift * Wide frequency bandwidth * Very low insertion losses * High immunity to external interference Accuracy - Dynamic performance data X e L Accuracy 2) @ IPN, TA = 25C, @ 15 V Linearity 2) Electrical offset voltage @ IP = 0, TA = 25C Residual offset voltage @ IP = 0 after an overload of 3 x IPN Thermal drift of offset voltage TA = - 25 .. + 85C Thermal drift of gain TA = - 25 .. + 85C Response time @ 90 % of IP di/dt accurately followed Frequency bandwidth (- 3 dB) 3) VOE VOM VOT eG TCe tr di/dt f 1 0.5 Max 10 10 2 0.05 <3 > 50 DC .. 50 % % mV mV mV/K %/K s A/s kHz * Current overload capability * Low power consumption * Wide dynamic range, 50 to 600 A in one package. Applications * AC variable speed drives and servo motor drives * Static converters for DC motor drives * Battery supplied applications * Uninterruptable Power Supplies (UPS) * Switched Mode Power Supplies General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards Safety EMC Deviation in output when tested to EN 61000-4-6 Deviation in output when tested to EN 61000-4-4 Notes : 1) 2) (SMPS) - 25 .. + 85 C - 25 .. + 85 C 75 g EN50178 (1994) EN50082-2 (1992) EN50081-1 (1992) < 10 % of IPN < 10 % of IPN * Power supplies for welding applications. LEM Components Overvoltage Category III, Pollution Degree 2 Excludes the electrical offset 3) Refer to derating curves in the technical file to avoid excessive core heating at high frequency 001107/1 www.lem.com Dimensions HAL 50..600-S (in mm) Bottom view Left view Secondary terminals Terminal Terminal Terminal Terminal 1 2 3 4 : supply voltage + 15 V : supply voltage - 15 V : output : 0V Front view Mechanical characteristics * General tolerance * Primary through-hole * Connection of secondary 0.5 mm 20 mm x 15 mm Molex 5045-04-A Remarks * VOUT is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed 90C. * This is a standard model. For different versions (supply voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us. LEM have a policy of continual product improvement and the company reserves the right to revise the above specification without prior notice. |
Price & Availability of HAL100-S |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |